Page 4
Section 4.1
Service Training
09.04
4.1.1.3 ADJUSTING VALVE CLEARANCE
The adjustment can be carried out when the engine is cool or warm after a cooling period of at least 30
minutes (oil temperature < 80 °C).
Valve clearance: Inlet 0.3 mm
Outlet 0.5 mm
adjustable
not adjustable
VALVE CLEARANCE SCHEMATIC
Crankshaft position 1
Turn the engine until the valve inlet and outlet of
cylinder 1 are just open.
Crankshaft position 2
Turn the engine one full revolution (360 °).
NOTE: When a new rocker cover is installed, increase the valve clearance by 0.1 mm. Adjust the valve
clearance to normal values after 50 service hours.