Section 4.1
Service Training
09.06
- Siide sealing ring onto injection valve using some grease
and insert injection valve.
NOTE: The notch on the injection valve must face
away from the claw. Marking faces exhaust
gas end.
- Mount claws and tum in bolts loosely.
- Fit new injection line with sealing rubber. Tighten cap nut
finger-tight.
NOTE: Sealing cones must be exactly in line when
mounting the injection line.
Re-bending is not allowed. Injection lines
must not be used twice.
- Tighten bolt of claws.
Specified tightening torque: 16